Computer Room, Server, Network, Temperature, Environment Monitoring & Alerting with Room Alert, TemPageR & Device ManageR! Computer Room, Server, Network, Temperature, Environment Monitoring & Alerting with Room Alert, TemPageR & Device ManageR!
Legal Notice
Customers
Guarantee
Primary Products
$995.00Room Alert 32W
$845.00Room Alert 32E
$595.00Room Alert 24E
$565.00Room Alert 12ER
$385.00Room Alert 4ER
$145.00Room Alert 3E
$215.00TemPageR 3ER
Click To View Product Detail
Room Alert
Avoid Disaster By Proactively Monitoring Computer Room Temperature, Humidity, Power, Flood, Smoke, Room Entry, Air Flow & More. Log Environment Sensor Data For Immediate Alert Notification, Historical Review & Graphing Or Use Room Alert’s Easy-To-Use Web Browser Interface For Viewing Real-Time Sensor Status Anywhere.
View Product Page
View Catalog
Model Comparison
Request Quote
Starts At Online
TemPageR
Monitor Temperature In 1 To 3 Locations Up To 200´ Apart. Be Alerted First If Your A/C Fails Or Temperatures Rise/Fall. Log Temperature Sensor Status For Historical Review & Graphing. Use TemPageR’s Web Browser Interface For Viewing Real-Time Sensor Status Anywhere.
View Intro Video
View Product Page
View Catalog
Model Comparison
Request Quote
Starts At
AVTECH News

Product Selection: AVTECH Software
Article Type: News Articles
Limit: All
AVTECH News Home View All AVTECH Software Articles View All News Articles
January 1, 2010
(View Original Article)

5 Things To Know About Data Center TemperatureKeep Airflow, Humidity & Other Considerations In Mind

Written By Sixto Ortiz Jr. - Processor Vol. 32 Issue 1
Temperature is a critical factor in the modern data center, and it is only becoming more so. Increased processor speeds, smaller server form factors, and higher server rack densities have all contributed to tremendous challenges for data center administrators in the areas of cooling and air movement.

These physical challenges, and management’s mandate to maintain asset availability at all times, means data center administrators must strive to make environmental factors such as temperature and humidity priority No. 1.

But how can data center administrators start making the right decisions in terms of temperature and humidity? Where should the appropriate limits be set? What technologies are available to tackle these issues?

Model The Flow
In any undertaking, it is extremely helpful to have a model that faithfully approximates reality and allows administrators to make effective decisions before they do any physical work. One option available to data center administrators is CFD (computational fluid dynamics).

Simply put, CFD is the mathematical modeling of data center environmental variables such as temperature and airflow. Carl Cottuli, vice president of product development and services at Wright Line (www.WRightLine.com), says CFD modeling essentially constructs a virtual representation of the data center. It models the impact of load distribution within the facility as well as the flow of hot and cold air within the space, adds Cottuli, who explains that CFD is useful for illustrating how to increase rack densities and server installations without creating additional hot spots and airflow issues.

Know What To Measure
A key factor of data center temperatures is knowing where to take measurements. After all, temperatures can vary widely depending on where readings are taken. This is important to know because taking temperature readings in the wrong spot can lead administrators down the wrong path, resulting in wasted time and money and potential damage to business-critical equipment.

Darren Bonawitz, co-owner of 1102 GRAND (www.1102Grand.com), a Kansas City-based data center, says administrators should avoid focusing on the entire room when taking temperature readings. Instead, he says, the inlet of IT equipment is what matters, so temperatures should be monitored there. These readings should drive any decisions made regarding data center temperatures, adds Bonawitz.

Dan Hyman, principal at Custom Mechanical Systems (www.CMSCooling.com), a provider of customized cooling systems for data centers, says the important temperature is that of the air entering the server rack, namely because this air is used to remove the heat generated by the server. The server is designed to work properly with a maximum temperature determined by the manufacturer, Hyman says; even though the server will work fine at lower temperatures, higher-temperature air will cause the server to overheat.

What's In A Number?
Monitoring and collecting data on environment variables such as temperature and humidity is only part of the battle. Knowing what to do with that data is really where the proverbial rubber meets the road. Again, it is essential to critically analyze this data so cost-effective decisions can be made. John Consoli, chief technology officer at AFCO Systems (www.AFCOSystems.com), says administrators should know the current TC 9.9 guidelines from ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers). Current ASHRAE guidelines provide a roadmap for fine-tuning temperature and humidity in the data center. These guidelines are the result of focused research work in this arena, so users can be confident that the guidelines have been well thought-out and developed.

Consoli believes most data centers are kept much colder than necessary, and 1102 GRAND’s Bonawitz agrees that administrators should consider raising the data center temperature. Data from IT hardware vendors indicates equipment can safely run at higher temperatures than previously thought, and this strategy can pay dividends, says Bonawitz: Increasing the temperature just one degree can save 3% or more off the data center energy bill. So, instead of shooting for 68 to 72 degrees Fahrenheit, administrators should find a comfort zone anywhere up to 80 F, which is within the range of 64.4 to 80.6 F recommended in the ASHRAE 9.9 guidelines.

Also, warns Bonawitz, administrators should make sure equipment fans are in sync with the change, or savings may be offset when more fan energy is utilized if the equipment thinks it is too hot. Additionally, harder-working fans add to a data center’s ambient noise.

Humidity Is Important, Too
Humidity control in the data center should not be overlooked. Daniel Calderon, facility director at Host.net, says it is important to keep a constant relative humidity of 40 to 55%. Too much humidity in the room can cause condensation that can in turn lead to server failures. Also, Calderon says condensation on CRAC unit coils can cause the unit to work harder. Too little humidity is also harmful, he adds: Not enough humidity in the air can cause static electricity.

In terms of humidity, ASHRAE 9.9 guidelines recommend a humidity of less than 60%, along with a lower dew point temperature of 41.9 F and an upper dew point temperature of 59 F. Additionally, a recent whitepaper published by the ASHRAE 9.9 Technical Committee recommends that, in addition to monitoring temperature and humidity, administrators should also make an effort to monitor and control dust and gaseous contamination, which can cause unwanted chemical, mechanical, or electrical effects on equipment.

Understand Airflow
For optimal tuning of data center conditions, it is important to understand the principles behind airflow management, says Wright Line’s Cottuli, who points out that cooling models in legacy data centers employ an open supply and return air methodology that drives mixing of both supply and return air streams. Cottuli says that overall statistics show that 40 to 50% or more of the energy consumption in a data center goes to cooling. But, he warns, these high percentages result in one to two times oversupply of cold air pumped into the system.

According to Cottuli, IT professionals need to understand the reasons behind this provisioning in order to run a more efficient and reliable data center. Thus, airflow patterns, including the effects of recirculation, air stratification, and bypass air, must be understood.

“Dramatically reducing these often overlooked issues and employing some common-sense data center practices will help you eliminate the chaos,” Cottuli adds.