Computer Room, Server, Network, Temperature, Environment Monitoring & Alerting with PageR Enterprise! Computer Room, Server, Network, Temperature, Environment Monitoring & Alerting with PageR Enterprise!
AVTECH Support
Support Tickets
Submit Ticket
Lookup Ticket
Knowledge Base
FAQs
Application Notes
Technical Articles
Announcements
Support Resources
License Key Request
Email-To-SMS Database
SNPP Database
TAP Dialup Database
Technical Glossary
Literature Downloads
Device ManageR
AVTECH Device ManageR Advanced Software For Discovery, Management, Logging, Graphing, Alerting And More Logo The All-In-One Solution For Discovery, Management, Logging, Graphing, Alerting & More Of AVTECH's IT & Facilities Environment Monitoring Hardware. Display Multiple Units Through A Single Web Interface, Set Up Multiple IP Addresses, View Multiple IP Cameras Across Your Network & More From Anywhere. Included With Room Alert & TemPageR.
FREE With Purchase! 
AVTECH Support

Product: Room Alert 24E
Article: Announcements
Limit: 10
View All Room Alert 24E Announcements View All Announcements
May 2, 2008

Room Alert 24E Firmware v3.0.1 AvailableRoom Alert 24E Firmware v3.0.1 Released 2 May 2008

AVTECH Software is pleased to announce that an update to the Room Alert 24E Firmware is available for download at AVTECH.com.

NOTE: AVTECH Device Discovery v3.0.3 or higher is required for this update

***Please Read The Following Before Updating***

NOTE: AVTECH Device Discovery v3.0.3 or higher is required for this update. Please be sure any web browsers currently accessing the unit are closed to be sure all files are updated correctly.

  • Resolved an issue that could cause SNMP Queries to stop responding after a period of time. The SNMP Community Name passed from the SNMP client was sometimes interpreted incorrectly resulting in an 'Access Denied' error.
  • Resolved an issue that could cause the MTU setting to not be applied correctly, preventing web access over VPN and other secure protocols. MTU settings from 512 to 1400 can now be configured for users experiencing an issue viewing the web interface over a VPN connection.
  • Resolved an issue that caused SNMP Trap messages to always be sent with a 'public' community string instead of the configured SNMP Community Name.
  • Added a 'View Tracing Output' option to the Advanced Settings screen. This is especially useful for determining the cause of SMTP email issues as it shows all activity happening 'behind the scenes', including communicatin with the email server.
  • Added the 'AM/PM' time formatting to email alerts if this time format is configured in the settings.
  • Added an option to disable the web interface for use in highly secure environments.
  • Added an option to disable TFTP firmware updates for use in highly secure environments.
  • Added an option to disable SNMP for use in highly secure environments.
  • Added additional entry validation checks to the settings pages to prevent against invalid settings entry.
  • Modified the 'getData.htm' output to be fully compatible with our new Device ManageR application.
  • Modified the 'Monitor Heat Index' label for Temp/Humidity Sensors on the Sensor Settings screen to open a popup linking to the explanation of what Heat Index is from the AVTECH.com Knowledge Base when clicked.
  • Modified the Security Settings screen to require the current password when changing to a new password.
  • For additional information about the updates included with Room Alert 24E v3.0.0 firmware, please click here.